Frequency converters
-
0.5-400Hz output frequency range
-
The optimal modulation technology to improve current waveform, lightweight slowdown in the operation fibrillation
-
Embedded standard RS485/RS422 serial communication interface, a built-PID closed-loop control functions
-
multi-function input and output terminals, intelligent control characteristics to meet the needs of different users
-
Start with the instantaneous power outage, many of the set speed, jumping frequency set, S-curve acceleration and deceleration, velocity feedback control, sound soft and hard protective function
-
Universal energy converter has a markedeffect, good speed, stable operation Soft StartMotor, the protectionfunction and the operationof automatic fault duagnosis is simple
-
Power scope: 0.4-400kW
-
Motor exclusive use of Intel microprocessor chips
-
Germany’s Siemens IGBT module, axial fan Taiwan, Japan electrolytic capacitor
-
SMD surface patch and components for the main components used in all large foreign company’s products
-
SVPWM optimization space vector control, harmonic output less silenced quiet
-
Design of wide voltage input 20% voltage is very suited to China’s national conditions
-
Powerfull, functional very gifted
-
Easy installation, simple operation and maintenance 2001, the lifelong maintenance
|

|
Models and meanings:
|
S |
- |
Enterprise code |
|
P |
- |
Frequency control |
|
P |
- |
Voltage-mode PWM control |
|
7C |
- |
Design № |
|
A3 |
- |
Three-phase general |
|
A2 |
- |
Two-phase general |
|
D1 |
- |
Universal singl-phase |
|
Q |
- |
Fans pump converter |
|
F |
- |
Injection-specific frequency converter |
|
H |
- |
Simple converter |
| Rated output |
|
| Rated current overload |
Rated current 150% 1 minutes |
| Voltage |
Three phase 380-440V/220-240V; 50-60Hz |
| Power input |
|
| Voltage frequency and phase |
Three phase 380-440V, 50/60Hz |
| Allow fluctuations |
Voltage: +10-15%, frequency: 5% |
| Anti-instantaneous voltage |
310V more continue to operate; dropped below the rated from 310V; continue to operate 15ms
310V above can continue to operate; dropped below the rated from 310V; continue to operate 15ms
160V above can continue to operate; dropped below the rated from 160V; continue to operate 15ms |
| Output frequency |
|
| The highest frequency |
50-400Hz variable set |
| Fundamental frequency |
50-400Hz variable set |
| Starting frequency |
50-400Hz variable set |
| Carrier frequency |
2-6kHz |
| Accuracy |
Setting: 0.3% of maximum frequency set value. No set: setting maximum value of 0.1% frequency |
| Resolution |
Setting: erqianfenzhiyi value of the highest frequency setting. Figure: 0.01Hz (99.99Hz below)and 0.1Hz (100Hz more) |
| Control |
|
| Process control |
PID (proportional standards, integral, differential, closed-loop cotrol) |
| Voltage/frequency |
With fundamental frequency can be set 320-440V |
| Torque upgrade |
Automatic: according to peak torque value; 0.1-20.0 coding manual setting |
| Torque |
More than 150% (torque vector control) |
| Canada, deceleration time |
0.1-3600s to accelerate, deceleration time can be set four separate option linear acceleration-decel eration curves |
| Subsidiary function |
Frequency limit and the lower frequency control, offset frequency, frequency setting gains, jumping frequency, Restart instantaneous power outage (speed tracking Restart), the current limit |
| Transhipment |
|
| Functioning operation |
Touch panel: Key operation and stop keys, remote operation. Terminal transformation: the important of instructions, reversw directions and other free operating instructions |
| Frequency set |
Touch panel: Eight key, V bond; Terminal input; More choice of frequency, analog signal: DC 0-5V frequency settingdevice or DC 4-20mA |
| The operating output |
Centralized alarm output. Open the way for the collector: the choice of operation, frequency of reach and frequency levels, testingor nine separate report. Output: the chice of frequency analog signal, the output current, torque, load rate (0-1mA) |
| Show |
|
| Digital display (LED) |
Output frequency, output current, output voltage, speed and other operational data |
| Liquid crystal display (LCD) |
Operational information, the operator guidance, functional code name of the data, fault information |
| HEC instructions (LED) |
Rechargeable, the data show flat touch panel operation instructions, the operating instructions |
| Brake |
|
| DC brake set |
Brake started frequency (0-60Hz);braking time (0-30s);braking force (0-200% variable set) |
| Protection function |
|
| Protection function |
Over-current, short circuit, grounding, over voltage, under and overload, overheating electrical over load, external alarm, surge protection devices from the main protection |
| Protective casing grades |
|
| Protective casing grades |
IP40 IP00 (IP20 so choose) |
|
Environment |
|
| The use of venues |
Indoor, 1000m below sea level, no corrosive gases, dust, direct sunlight |
| Temperature/humidity |
- 10 - +50oC/20-90% RH not dewing (22kW over 40oC) in the following specifications |
| Vibration |
5.9M/s2 (0.6G) below |
| Storage temperature |
applicabletrancporation short-keeping |
| Cooling |
|
| Cooling |
Forced air cooling |
|
|